Once the covers look right, write down the designer's assumptions about the design as assertions. For the lift these are the safety properties in the wrapper:

AssertionDesigner's intuitionExpected
a_door_not_movingNever move with the door openproven (the FSM encodes it)
a_no_wrapNever try to go above floor 3 or below floor 0proven
a_one_floorEach MOVE changes the floor by exactly one in the travel directionproven
a_open_for_callThe door only opens for a callproven
a_clear_servedA call is only forgotten when that floor is servedproven

a_no_wrap is a nice example of formal checking something a designer "knows" is impossible. The 2-bit floor + 1 would silently wrap from 3 to 0 — but the controller only moves up when there is a call above it. The proof confirms that reasoning for every possible sequence of button presses.